Medical Speech Recognition using Whisper

Overview

End-to-end fine-tuning of OpenAI Whisper-small for medical-domain speech recognition. General-purpose ASR models handle everyday English well but degrade on symptom descriptions and medical vocabulary, so this project builds the full path: dataset design, a leak-free train/validation/test split, W&B-tracked fine-tuning, checkpoint publication to the Hugging Face Hub — and, most importantly, a held-out evaluation harness that measures the result against the stock baseline under an identical decoding protocol.

Data & Split

Built on the public PaulMooney Medical ASR dataset on Hugging Face. The source partitions are misleadingly named — the bulk of the audio (5,895 clips) sits in the test split — so the data was restructured into a three-way split with clear semantics: 5,395 clips for training, 381 for validation (used only for checkpoint selection), and a 500-clip test set held untouched until final scoring (seed 42).

Source audio is 44.1 kHz stereo; everything is resampled to 16 kHz mono before it reaches the model — the Whisper input contract, enforced identically in training and evaluation.

Training

Fine-tuned with the Hugging Face Seq2SeqTrainer: 1,000 steps (≈6 epochs), learning rate 1e-5 with linear warmup, batch size 32, fp16 mixed precision, and gradient checkpointing. Validation WER is computed every 100 steps and the best checkpoint is kept automatically.

The run is tracked in Weights & Biases, and the final checkpoint is published on the Hugging Face Hub as oegbo/whisper-small-medical-v2, fine-tuned from openai/whisper-small.

Training loss over 1,000 fine-tuning steps

Training loss over 1,000 steps

Validation loss per evaluation step

Validation loss per evaluation step

Validation WER per evaluation step

Validation WER per evaluation step (drives best-checkpoint selection)

Evaluation

The held-out test set (all 500 clips, none used for training or model selection) is scored for both the stock baseline and the fine-tuned model under an identical, constrained decoding protocol: fixed English language, no-repeat n-gram, and repetition penalty applied to both models — no exclusions of any clip.

The harness caught two real problems during development, both fixed before the reported numbers: an input-pipeline bug, where native 44.1 kHz audio was initially fed to a 16 kHz-assuming pipeline and produced meaningless scores; and a repetition-loop hallucination from unconstrained decoding that dominated one model’s aggregate WER. Full diagnosis is in the notebook.

Results

Normalized WER (lowercase, punctuation-stripped — standard ASR reporting practice), 500 held-out clips: stock baseline 11.0% → fine-tuned 5.4%, a 51% relative reduction. Raw WER: 20.6% → 12.7%.

ModelRaw WERNormalized WER
openai/whisper-small (stock)20.6%11.0%
Fine-tuned (v2)12.7%5.4%

Per-clip analysis shows the fine-tuned model improving on most clips. A small number of test clips where both models produce similar text that differs from the reference suggest noise in the source dataset; these were retained in scoring for both models.

Transcription Examples

REF: I have a foot ache after running 500m with my running shoes.

BASE: I have a food tech after running 500 meter with my running shoes.

FT: I have a foot ache after running 500m with my running shoes.

REF: I have found some issues in my skin and tried to use cream but it doesn’t get better.

BASE: I have found some issues in my screen and tried to use screen but it doesn’t get better.

FT: I have found some issues in my skin and tried to use cream but it doesn’t get better.

REF: I got a divorce last year and I just can’t stop dwelling on how to get revenge on my ex husband.

BASE: I got a divorce last year and just can’t stop dwelling on how to get revenge my ex-husband.

FT: I got a divorce last year and i just can’t stop dwelling on how to get revenge on my ex husband.

REF: I can’t do anything I feel a weak in my body

BASE: Everything I felt in my blood.

FT: Everything I felt in my body

Neither model recovers this reference; clips like this are retained in the WER for both models — no exclusions.

Verbatim outputs from the 500-clip held-out evaluation (the notebook prints the first ten clips; four representative examples shown here).

What I’d Do Next

Three changes would move this from a clean benchmark to a usable clinical component. First, scale and diversify the data: the corpus is small by ASR standards, and a random split cannot rule out the same speaker appearing on both sides, so a speaker-disjoint test set drawn from real clinical conversation — multiple accents, background noise, overlapping speech — is the single highest-value improvement.

Second, measure what matters clinically. The reported scores use normalized text (lowercase, punctuation stripped), which is the right way to compare models but hides exactly the errors that break downstream use: drug names, dosages, and anatomy terms. Reporting a domain-term error rate, and restoring casing and punctuation, would show whether the model is safe for anything beyond transcription demos.

Third, explore the modelling headroom: a larger Whisper checkpoint (medium or large-v3), domain-adapted decoding with contextual biasing or a medical language model, and a robustness sweep with added noise and reverberation. Publishing the evaluation script and split alongside the checkpoint would make all of this directly comparable.